no event-filter tapsender filter-name <eventType> index <indexNumber>

Prev Next

Deletes an event filter rule using its index value in an event filter list. Event rules filter out all events that are sent from a Network Security appliance to Helix for a specified event type or for all event types.

Note

Helix integration is not supported on the NX x3xx appliances and the NX 10000 appliance.

Important

Make sure the Evidence Collector module is enabled before you add or delete event filter rules. Use the show tapsender status command.

Important

Your event filter configuration changes will not take effect until you apply the changes. The status pending or mark_deleted appears in the show event-filter tapsender configuration <eventType> command output if you did not apply the changes.

Syntax

no event-filter tapsender filter-name <eventType> index <indexNumber>

Parameters

<eventType>

The event type.

<indexNumber>

The index number for the filter rule.

Example

The following example deletes the HTTP event type filter rule that has the index number 0:

hostname (config) # no event-filter tapsender filter-name http index 0
hostname (config) # event-filter tapsender config apply

User role

Admin or Operator

Command mode

Config

Supported appliances

This command is supported on the following appliances running the specified releases or later:

  • Network Security: Release 8.1