Deletes an event filter rule using its index value in an event filter list. Event rules filter out all events that are sent from a Network Security appliance to Helix for a specified event type or for all event types.
Note
Helix integration is not supported on the NX x3xx appliances and the NX 10000 appliance.
Important
Make sure the Evidence Collector module is enabled before you add or delete event filter rules. Use the
show tapsender statuscommand.
Important
Your event filter configuration changes will not take effect until you apply the changes. The status
pendingormark_deletedappears in theshow event-filter tapsender configuration <eventType>command output if you did not apply the changes.
Syntax
no event-filter tapsender filter-name <eventType> index <indexNumber>
Parameters
<eventType>
The event type.
<indexNumber>
The index number for the filter rule.
Example
The following example deletes the HTTP event type filter rule that has the index number 0:
hostname (config) # no event-filter tapsender filter-name http index 0 hostname (config) # event-filter tapsender config apply
User role
Admin or Operator
Command mode
Config
Supported appliances
This command is supported on the following appliances running the specified releases or later:
Network Security: Release 8.1