Reviewing alert aging settings using the CLI

Prev Next
To review alert aging settings using the CLI:
  1. Enable the CLI configuration mode:

    hostname > enable hostname # configure terminal

  2. List alert aging settings:

    hostname (config) # show hx server detection

    The following is sample output from this command:

    HX Server Detection Configuration:

    Generated Indicator Aging: enabled
    Generated Indicator Aging Period: 14 days
    Generated Condition Aging: enabled
    Generated Condition Aging Period: 30 days
    Source Alert Aging: enabled
    Source Alert Aging Period: 30 days
    Alert Aging Period: 30 days
    False Positive Alert Aging Period: 1 day
    

    Intel Matching: enabled

    Legacy notification listener active: no
    Malicious.URL Indicator Generation (legacy): yes
    Suspicious (noisy) Indicator Generation (legacy): no
    Inbound alert poll interval: 5 minutes
    Inbound alert minimum severity: majr
    No ignored alert types. 

    Last bookmark ID: 0