show fenet dti proxy configuration

Prev Next

Shows basic configuration settings for the DTI cache on the Central Management System appliance.

Note

These configuration settings should be changed only under the guidance of Trellix Technical Support.

Syntax

show fenet dti proxy configuration

Parameters

None

Output fields

The following table describes the output fields for this command.

Field

Description

DTI Proxy Cache State

Whether the cache proxy is running.

Listening Port

The port the cache proxy listens to for incoming requests from the Central Management System appliance.

Cache Size

The size of the DTI cache, in megabytes.

Maximum Cache-able Object Size

The maximum size for a file in the DTI cache, in bytes.

Minimum Cache-able Object Size

The minimum size for a file in the DTI cache, in bytes.

Example

The following example shows basic DTI cache configuration.

cm-02 > show fenet dti proxy configuration

DTI Cache Proxy State:            running
DTI Cache Proxy Configurations:
  Listening Port:                   8443
  Cache Size:                       130000 MB
  Maximum Cache-able Object Size:   26843545600 bytes
  Minimum Cache-able Object Size:   1 bytes

User role

Admin, Operator, or Monitor

Command mode

Standard

Supported appliances

This command is supported on the following appliances running the specified releases or later:

  • Central Management System: Release 7.7