The table below provides the technical specifications for the Trellix CM 4600.
Component | CM 4600 Specifications |
|---|---|
Form Factor | 1U Chassis |
Weight of Appliance | 32.3 lbs |
Weight of Packaged Appliance | 39.3 lbs |
Dimensions (W x D x H) | 17.2" (437 mm) X 19.98" (507 mm) X 1.7” (43 mm) |
Enclosure | 1 RU, fits 19-inch Rack |
Management Interfaces | (1) 10/100/1000BASE-T Ports |
HA link/HA backup link/ Management Interfaces | (3) 10/100/1000BASE-T Ports |
Memory | 64 GB (2 x 32 GB) |
Drive Capacity | (4) 4 TB HDD, RAID 10, 3.5 inch, FRU |
AC Power Supply | Redundant (1+1), FRU, 400W with Input 1100-240VAC / 6.0 – 3.0A | 200-240VDC / 3.4- 3.2A, 50-60 Hz IEC60320- C14 inlet |
Maximum Power Consumption | 300 W |
Operating Temperature | 5° to 35° C (41°F - 95°F) |
Maximum Thermal Dissipation | 1024 Btu/hr |
Relative Humidity | Operational standard: 90% RH Non-operational standard: 95% RH NoteThe appliance box can work under 90% RH, and can also be stored (powered off) at 95% RH for a short period of time. It is not recommended to store any electronics in high humidity places for an extended period of time. |