PX 7600 Hardware Administration Guide

Prev Next

Compliance Number: FEI-018


The PX 7600

Front-facing PX 7600 appliance — rack-mounted black front panel with perforated grille, FireEye logo at center, drive bay openings, and PX 7600 label on the right edge.

The FireEye PX 7600 is a powerful forensics tool that continuously captures packets at a high rate of speed without loss. It enables packet search and retrieval in minutes using an intelligent real-time indexing method.

The Front View

Close-up front view of the PX 7600 front panel showing perforated grille, status LEDs, and ventilation openings; red circles mark two highlighted front features.

Front-left panel detail — vertical control area with power button and indicator icons circled in red.

Annotated diagrams — left: numbered control-panel diagram with labels 1–8 corresponding to front indicators and buttons; right: circular close-up of rear connectors showing labels 9 and 10.

1. Power button

The main power switch applies or removes primary power from the power supply to the server but maintains standby power. Unplug the appliance before servicing.

2. Reset Button

Reboots the system.

3. Power LED

Steady on

Power on

Blinking at 4Hz

Checking BIOS/BMC integrity

Blinking at 4Hz and "i" LED is blue

BIOS firmware updating

Two blinks at 4Hz, one pause 2hz and "i" LED blue

BMC firmware updating

Blinking at 1Hz and "i" LED red

Fault detected

4. LAN 1 LED

Indicates network activity on a LAN when flashing; defaults to the first two ports of CPU1 AIOM.

5. Power Failure LED

Indicates a power supply module has failed.

6. HDD Activity LED

Indicates activity on the hard drive when flashing.

7. LAN 2 LED

Indicates network activity on a LAN when flashing; defaults to the first two ports of CPU1 AIOM.

8. Information LED

Alerts operator to several states:

Red, solid

An overheat condition has occurred

Red, blinking at 1Hz

Fan failure, check for an inoperative fan

Red, blinking at 0.25Hz

Power failure, check for a non-operational power supply

Red, solid, with Power LED blinking green

Fault detected

Blue and red, blinking at 10 Hz

Recovery mode

Blue, solid

UID has been activated locally to locate the server in a rack environment

Blue, blinking at 1Hz

UID has been activated using the BMC to locate the server in a rack environment

Blue, blinking at 2Hz

BMC is resetting

Blue, blinking at 4Hz

BMC is setting factory defaults

Blue, blinking at 10Hz with Power LED blinking green

BMC/BIOS firmware is updating

9. Drive Device LED

Each drive carrier has two LED indicators: an activity indicator and a status indicator.

10. Drive Device LED

Each drive carrier has two LED indicators: an activity indicator and a status indicator.

Drive Carrier LED Indicators

Each drive carrier has two LED indicators: an activity indicator and a status indicator. For RAID configurations using a controller, the meaning of the status indicator is described in the table below.

LED Type

Color

Blinking Pattern

Meaning of Blinking Pattern

Activity LED

Blue

Solid On

Idle SAS/NVMe drive installed.

Blinking

I/O activity.

Off

Idle SATA drive installed.

Status LED

Red

Solid On

Failure of drive with RSTe support.

Blinking at 1 Hz

Rebuild drive with RSTe support.

On for five seconds, then off

Power on for drive with RSTe support.

Red

Blinking at 4 Hz

Identify drive with RSTe support.

Green

Solid Green LED

Safe to remove NVMe device.

Amber

Blinking at 1Hz

Do not remove NVMe device.

Chassis

Front chassis line drawing of PX 7600 showing multiple hot-swappable disk drive bays and front panel components.

  1. Disk Drive Carrier: Each carrier can house a hot-swappable disk drive. A drive slot map displays the disk slot numbers on top of the appliance.

  2. Handle Release: Press this tab to release the handle. Use the handle to pull the disk drive carrier from the chassis.

The Rear View

[IMAGE PLACEHOLDER: Rear view of the PX 7600 rear panel showing numbered callouts 1 through 14 above ports and connectors]

1. Power Supply 1

8. USB 3.0 Ports

2. Power Supply 2

9. Serial Port

3. Capture Port 4 (4-7 in 10G mode)

10. ether1 (RJ45) Management Port

4. Capture Port 0 (0-3 in 10G mode)

11. ether2 (RJ45) Management Port

5. 1PPS SMA connector

12. ether3 (SFP+) Management Port

6. IPMI Port

13. ether4 (SFP+) Management Port

7. VGA Connector

14. SAS ports for SX 5000 connections

Power Port

  • Power: Connect your power source to this port to provide power to the appliance. The appliance comes with one redundant power supply unit for use if the primary unit fails.

I/O Ports

  • Serial Console: Connect to this port to manage the appliance from your terminal. Communication settings for the serial port are 115200 baud, 8 data bits, no parity, 1 stop bit.

  • Video: Connect a monitor to this port to view the appliance's command-line interface.

  • USB 3.0: These ports are USB 3.0 compliant.

SAS Ports

Connect a appliance to an SAS port to provide that appliance with additional storage.

Power Supply Indicator

LED Color and State

Power Supply Condition

Solid Green

Indicates that the power supply is on.

Blinking Green

Indicates that the power supply is plugged in and turned off by the system.

Blinking Amber

Indicates that the power supply has a warning condition and continues to operate.

Solid Amber

Indicates that the power supply is plugged in, and is in an abnormal state. The system might need service.

OFF

No AC power to modules.

Management Ports

IPMI: Connect for access to out-of-band management functions, including power control, console redirection, and appliance health status.

Management ports 1 and 2 are 100/1000/10GBASE-T RJ45

Management ports ether3 and ether4 are SFP+ connectors. The SFP+ connectors accept the following modules:

Module

SKU

10GBASE-SR/1GBASE-SX (LC MMF)

SXSR1G10GNX-HW

10GBASE-LR/1GBASE-LX (LC SMF)

LXLR1G10GNX-HW

10GBASE-CU_5mDAC (5 m direct attach cable)

BASECU10GNX-HW

1GBASE-T (RJ45)

BASET1GNX-HW

Capture Ports

orange exclamation-in-circle warning icon

IMPORTANT

You must not press CTRL-C at any time during capture port configuration. Doing so means packet capture may not work. If you press CTRL-C during configuration, you must re-run the configuration command.

The capture ports 0 and 4 can be used either in 40 Gbps mode or 10 Gbps mode. The default mode is 40 Gbps mode. To convert the cards to 10 Gbps mode, connect a hydra cable that multiplexes the connection to 4 10 Gbps ports. In addition, configure the change using the CLI to complete the conversion.

The capture ports 0 and 4 can be used either in the following modes:

  • 2 * 40 GBASE-SR4 mode. In this mode, both QSFP+ interfaces of the capture card must be set to 40 GBASE-SR4. You must use the patch cable, and the link partner must also run 40 GBASE-SR4.

  • 8 * 10GBASE-SR mode. In this mode, both QSFP+ interfaces of the capture card must be set to 4 * 10 GBASE-SR. You must use the fanout cable, and the link partner must also run 4 * 10 GBASE-SR.

NOTE

1 * 40GBASE-SR4 + 4 * 10GBASE-SR mode is not supported.

Use CLI commands to change between the two modes and select the corresponding cable for your connections

You must order two SR40G-HW optics and two fanout cables or two patch cables:

Module

SKU

40GBASE-SR4

SR40G-HW

For 8 x 10G mode fiber order 2 x MPO to LC (1:4) OM3 MMF 5m breakout cable

FANOUTCABLE

For 2 x 40G mode fiber order 2 x MPO to MPO 12 strand Type B MMF 5m OM3 fiber

NOTE

Uncertified transceiver modules are not supported.

Installation

This topic provides information about the site requirements of your installation location.

Before You Begin

Follow the steps in this topic before you install the appliance.

Before opening the box:

  • Review the packing slip contained in the plastic slip attached to the top of the box. Ensure the shipment contains the correct appliance.

  • Ensure the serial number listed on the packing slip matches the one specified on the sticker located on one side of the box.

  • If there appears to be damage to the box, file a damage claim with the carrier who delivered it.

Unpacking the appliance:

  • Carefully remove the appliance from the box in an area away from heat, electrical noise, and electromagnetic fields.

  • Ensure the box contains:        

    • The correct appliance model

    • Online Documents Portal Referral

Installation Site Guidelines

Follow these guidelines when you select an installation site:

  • Leave enough clearance in front of the rack for its door to open completely without obstruction.

  • Avoid environments that produce heat, electrical noise, and electromagnetic fields.

  • Only install the appliance in a restricted access location such as a service closet or dedicated equipment room.

  • Make sure the location is properly ventilated.

  • Make sure there is sufficient space for air flow.

  • Make sure the location is positioned for safe access for maintenance.

Rack Precautions

FireEye recommends that you mount the appliance in a standard 19-inch rack. The vertical hole spacing on the rack rails must meet standard ANSI/EIA-310-C requirements.

Consider the following before installing your appliance in the rack:

  • Ensure the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.

  • In a single-rack installation, stabilizers should be attached to the rack.

  • In a multiple-rack installation, the racks should be coupled together to increase their stability.

  • Always make sure the rack is stable before extending a component from the rack.

  • Only extend one component from the rack at a time—extending two or more simultaneously may cause the rack to become unstable.

  • Ensure your rack meets the safety requirements of UL 60950-1.

WARNING

STABILITY HAZARD: The rack may tip over causing serious personal injury. To prevent injury:

  • Before extending the rack to the installation position, read the installation instructions.

  • Do not put any load on the slide-rail mounted equipment when the rails are extended in the installation position.

  • Do not leave the slide-rail mounted equipment with the rails extended in the installation position.

Server Precautions

FireEye recommends reviewing the electrical and general safety precautions that came with each component you intend to install in the rack.

Review the following before installing the appliance in the rack:

  • Determine the placement of each component in the rack.

  • Ensure there is a minimum clearance of six inches behind the chassis to allow for easy cable management.

  • Install the heaviest component at the bottom of the rack first, then move up.

  • Allow hot-swappable power supply units, disk drives, and transceivers to cool before handling them.

  • Use a regulating uninterruptible power supply to protect your components from voltage spikes, power surges, and failure during a power outage.

  • Keep all of the rack's doors and panels closed when you are not servicing the components.

Rack-Mounting Precautions

Consider the following safety precautions when you install the appliance in the rack:

  • Make sure the appliance is grounded at all times to prevent damage from electrostatic discharge.

  • Use an electrostatic wrist guard when handling the appliance.

  • At least two technicians should be involved to install the appliance safely.

  • FireEye recommends only individuals with rack-mounting experience should install the appliance.

  • Install the appliance in an environment compatible with the manufacturer's maximum recommended ambient temperature (TMRA) for each component in your rack.

Ventilation Requirements

Ventilation and optimal location are essential to the proper operation of the PX 7600 appliance. Give the unit at least six inches of space around ventilation openings so that adequate ventilation is possible.

The PX 7600 appliance draws air through the front and expels it out the back. Note the direction of the air intake and exhaust of the other components in the rack to ensure safe ventilation of all components involved.

Cabling Requirements

The PX 7600 appliance ships with the following cables:

  • (2) 6 ft (1.83 m) AC power cord, SVT, 60 °C, 3x18 AWG (0.824 mm²)

You must provide any additional cables required to connect your system to the network and other devices. Do not exceed the maximum run length of the additional cables you provide.

Attaching Cables To The Appliance

  • Connect the PX 7600 appliance to one or more network devices using the cables appropriate to the deployment of your choice.

  • Connect the power cable or cables to the power port or ports on the back of the appliance.

Replacements

Return Process

If you believe you have a defective part or system, you must first contact FireEye Technical Support, who will validate the claim. If the part or system is defective, Technical Support will initiate a Return Materials Authorization (RMA) and guide you through the process.

For more information, see www.fireeye.com/support/contacts.html.

Removing and Replacing a Disk Drive

To replace a disk drive in the PX 7600, order a 16TB w/ SMC Toolless Tray (FRU: 427-HDD35-16TB-A4-SAS ).

Perform the following steps to remove and replace a disk drive:

  1. Remove the bezel at the front of the appliance by sliding the release tab to the right and pulling the bezel away from the chassis.

  2. Locate the disk drive carrier that contains the failed disk drive. The carrier should have a red LED.

  3. Push the button on the right to release the latch handle.

  4. Pull the handle to slide the disk drive from its slot.

  5. Insert the new disk drive carrier into the available slot and push in until it clicks.

Removing and Replacing a Power Supply Unit

To replace the PX 7600 power supply, order a Supermicro 1200W Titanium Redundant PS (SMC SKU: PWS-1K23A-1R) (FRU: 428-PWRSUP-1K23A-1R).

Perform the following steps to remove and replace a power supply unit (PSU):

  1. At the rear of the appliance, remove the power cable from the failed PSU.

  2. While gripping the handle to the left of the power port and pressing the release lever to the right of it, pull out the failed PSU.

  3. Insert the replacement PSU in the open slot and slide it in until it clicks into place.

  4. Attach the power cable to the new power supply.

Appendix 1: System Specifications

The table below provides the technical specifications for the FireEye PX 7600.

Component

PX 7600

Form Factor

2U Rack-Mount, 17.2 in. x 3.5 in. x 25.5 in. (depth) (43.7 cm x 8.9 cm x 64.7 cm)

Weight of Appliance

70 lbs (31.75 kg)

Weight of Packaged Appliance

81.15 lbs (36.81 kg)

Dimensions (W x D x H)

2U: 17.2 in. x 3.5 in. x 25.5 in. (depth) (43.7 cm x 8.9 cm x 64.7 cm)

Enclosure

2 RU, fits 19-in. rack

Management Interfaces

(2) SFP+ Ports

IPMI

(1) 10/100/1GBASE-T Ports

Capture Interfaces

(2) QSFP Ports

SAS Connectors

(4) SFF-8644 mini-SAS HD External Connectors

Memory

256 GB

Drive Capacity

(12) 10TB HDD 3.5 in. FRU # 427-HDD35-10TB-A4-SAS

(12) 16TB HDD 3.5 in. FRU # 427-HDD35-16TB-A4-SAS

3.5 in. FRU

AC Power Supply

Redundant (1+1), FRU,

1000W (100 - 127Vac) 15A-12A / 50-60Hz

1200W (200 Vac- 240 Vac) 8.5-7A / 50-60Hz

IE60320-C14 inlet

Maximum Power Consumption

400W-700W (Normal Operation) 1100W ( Artificial Maximum)

Operating Temperature

0° C to 35° C

Maximum Thermal Dissipation

3753 BTU/hour

Appendix 2: Product Compliance Information

The following table lists the electromagnetic compatibility (EMC), low voltage directive (LVD), safety, and other regulatory standards met by the FireEye PX 7600 appliance.

EMC

LVD/Safety

Environmental

FCC Part 15 Class-A, CE (Class-A),

CAN/CSA 22.2 No. 62368

RoHS

CNS 13438,

UL 62368

REACH

CISPR 32, VCCI-CISPR32,

IEC 62368, EN 62368

WEEE

EN 55035, EN 55032, EN 61000,

BS EN 62368

Conflict Minerals

ICES-003, KN 32, KN 35

Technical Support: https://support.trellix.com