Parameter | State or category | ATD-3200 and ATD 6200 | ATD-3100 and ATD 6100 | ATD-3000 | ATD-6000 |
|---|---|---|---|---|---|
Temperature | Operating |
|
| +10°C to +35° C (+50°F to + 95°F) with the maximum rate of change not to exceed 10°C per hour | +10º C to +35º C (+50ºF to +95ºF) with the maximum rate of change not to exceed 10°C per hour |
Shipping | -40º C to 70º C (-40º F to 158º F) | -40º C to 70º C (-40º F to 158º F) | -40°C to +70°C (-40°F to +158°F) | -40°C to +70°C (-40°F to +158°F) | |
Altitude | Operating | Support operation up to 3050 meters (10,000 feet) with ASHRAE class deratings | Support operation up to 3050 meters (10,000 feet) with ASHRAE class deratings | Support operation up to 3050 meters (10,000 feet) | Support operation up to 3050 meters (10,000 feet) |
Humidity | Shipping | 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) | 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) |
|
|
Shock | Operating | Half sine, 2 g peak, 11 milliseconds | Half sine, 2 g peak, 11 milliseconds | Half sine, 2 g peak, 11 milliseconds | Half sine, 2 g peak, 11 milliseconds |
Unpackaged | Trapezoidal, 25 g, velocity change is based on packaged weight | Trapezoidal, 25 g, velocity change is based on packaged weight | Trapezoidal, 25 g, velocity change 136 inches/second (≧40 lbs to < 80 lbs) | Trapezoidal, 25 g, velocity change is based on packaged weight | |
Packaged | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs) |
| |
Vibration | Unpackaged | 5 Hz to 500 Hz, 2.20 g RMS random | 5 Hz to 500 Hz, 2.20 g RMS random | 5 Hz to 500 Hz, 2.20 g RMS random | 5 Hz to 500 Hz, 2.20 g RMS random |
Packaged | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | 5 Hz to 500 Hz, 1.09 g RMS random | ||
AC-DC | Voltage | ATD-3200
ATD-6200
| ATD-3100
ATD-6100
| 100 - 240 V at 5.8 Amps | 100 - 240 V. 8.5 Amps |
Frequency | 47 Hz to 63 Hz | 47 Hz to 63 Hz | 50 - 60 Hz | 50 - 60 Hz | |
Source Interrupt | No Loss of data for power line drop-out of 12 milliseconds | No Loss of data for power line drop-out of 12 milliseconds | |||
Surge (Operating and non-operating) | Unidirectional | Unidirectional | |||
Line to earth Only |
|
| |||
ESD | Air Discharged | 12.0 kV | 12.0 kV | +/-12 KV except I/O port +/- 8 KV per Environmental test specification | 12.0 kV |
Contact Discharge | 8.0 kV | 8.0 kV | 8.0 kV | ||
Acoustic noise | Power level <300 W | 7.0 BA | 7.0 BA | Sound power: 7.0 BA in operating conditions at typical office ambient temperature (23 +/- 2 degrees C) | Sound power: 7.0 BA in operating conditions at typical office ambient temperature (23 +/- 2 degrees °C) |
Power level >300 W | |||||
Power level >600 W | |||||
Power level >1000 W | |||||
Certifications | Safety certification | UL 1950, CSA-C22.2 No. 950, EN-60950, IEC 950, EN 60825, 21CFR1040 CB license and report covering all national country deviations | UL 1950, CSA-C22.2 No. 950, EN-60950, IEC 950, EN 60825, 21CFR1040 CB license and report covering all national country deviations | ||
EMI certification | FCC Part 15, Class A (CFR 47) (USA) ICES-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (Int'l) | FCC Part 15, Class A (CFR 47) (USA) ICES-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (Int'l) |