email autosupport event <event_name>

Prev Next

Enables sending of the specified event to autosupport.

Syntax

email autosupport event <event_name>

Parameters

no

Disables notification emails for the specified event.

event_name

The events for which to send autosupport notification emails.

  • process-crash—A process in which the system has crashed.

  • disk-space-low—Free disk space is low (enabled by default).

  • disk-space-ok—Free disk space returned to normal(enabled by default).

  • cmc-new-client—A new potential CMC client has announced itself.

  • cmc-status-failure—The CMC has detected an error in a managed appliance.

  • cmc-status-ok—A CMC status error has been corrected.

  • cmc-version-mismatch—The CMC connected to an appliance with a different system software version.

  • smart-warning—Disk warnings generated by the Self-Monitoring, Analysis and Reporting Technology (SMART) system (disabled by default).

  • interface-up—An interface’s link state has changed to up.

  • interface-down—An interface’s link state has changed to down.

  • user-login—User logged in to the system.

  • user-logout—User logged out of the system.

  • syslog-rotation—System log files rotation.

  • excessive-temperature—Excessive temperature is reached

  • normal-temperature—Temperature is normal.

  • raid-status-failure—A Redundant Array of Inexpensive Disks (RAID) error has occurred.

  • raid-status-recover—A RAID has been recovered.

  • physical-disk-failure—A physical disk has failed.

  • physical-disk-recover—A physical disk has been recovered.

  • power-supply-failure—A power supply has failed.

  • power-supply-recover—A power supply has been recovered.

  • fan-failure—A fan has failed.

  • fan-recover—A fan has been recovered.

  • license-state-changed—A license state has changed.

  • security-update-failure—Security update has failed.

  • unexpected-failover—An unexpected fail-over on CMS-HA has occurred.

  • manual-failover—A manual fail-over on CMS-HA has occurred.

  • nxha-health-failure—NX-HA health check failed.

  • mvx-cluster-state-changedMVX cluster state changed.

  • mvx-cluster-util-threshold-exceededMVX cluster utilization has exceeded threshold.

  • http-throughput—HTTP throughput has not increased for a specified time.

  • hardware-bypass-entered—Permanent hardware bypass mode entered.

  • inline-engine-up—Inline packet inspection process has started (IPS-enabled appliances only).

  • inline-engine-down—Inline packet inspection process has stopped (IPS-enabled appliances only).

  • if-link-change—An interface link has changed.

  • faas-vpn-status-change—Status of FaaS VPN has changed.

  • token-state-change— Virtual appliance activation state is changed.

  • dupe-appliance-detected—A duplicate virtual appliance detected.

  • token-server-unreachable—Token Server is unreachable.

  • token-server-reachable—Token Server is reachable.

User role

Admin, Operator, or Analyst

Command mode

Config

Supported appliances

This command is supported on the following appliances running the specified releases or later:

  • Email Security — Server: Before Release 7.6.0