Make sure an appliance meets regulatory and environment requirements.
SuperMicro-based platforms
Trellix 1U | Trellix 2U or 3U | |
|---|---|---|
Electromagnetic emissions | FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3 CISPR 22 Class B | FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3 CISPR 22 Class B |
Electromagnetic immunity | EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) 55024 | EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4--4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) 55024 |
Safety | EN 60950/IEC 60950-Compliant, UL Listed (USA) CUL Listed (Canada) TUV Certified (Germany) CE Marking (Europe) | EN 60950/IEC 60950-Compliant, UL Listed (USA) CUL Listed (Canada) TUV Certified (Germany) CE Marking (Europe) |
DAS
Certification marks | ED, NRTL, RCM, KCC, BSMI, IRAM, EAC |
Standards certified to | EN60950-1, EN55032, EN55024 |
Regions covered | U.S. and Canada, European Union, APAC, LTAM |
Other countries with certification | Japan, Israel, South Africa, Ukraine, Morocco |
DAS-120, DAS-250 | |
|---|---|
Input voltage | 100–240 VAC |
Input frequency | 50/60 Hz |
Power supply | 800 W X2 |
Power consumption | DAS-120 - 331 W DAS-250 - 663 W |
Amps (Max) | 10@100-127 VAC 5@200-240 VAC |
Altitude (Max) | 10,000 ft @ 68º F |
Temperature (Max) | 0º to 35º C (32º to 95º F) operating –20º to 60º C (-4º to 140º F) non-operating |
BTU | DAS-120 - 1331 BTU/HR DAS-250 - 2661 BTU/HR |
Humidity | Operating — 20% to 80% (non-condensing) |
Intel-based platforms
Parameter | Limits |
|---|---|
Operating temperature | +10° C to +35° C with the maximum rate of change not to exceed 10° C per hour |
Non-operating temperature | –40° C to +70° |
Non-operating humidity | 90%, non-condensing at 35° C |
Acoustic noise | Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23 ± 2 degrees C) |
Shock, operating | Half sine, 2-g peak, 11 msec |
Shock, unpackaged | Trapezoidal, 25 g, velocity change 136 inches/sec (≧ 40 lbs to > 80 lbs) |
Shock, packaged | Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs) |
Shock, operating | Half sine, 2-g peak, 11 mSec |
Vibration, unpackaged | 5 Hz to 500 Hz, 2.20 g RMS random |
ESD | ±12 kV for air discharge and 8 K for contact |
System cooling requirement in BTU/Hr | 1660 BTU/hour |
Parameter | Limits | |
|---|---|---|
Temperature | Operating |
|
Shipping | –40°C to 70°C (–40°F to 158°F) | |
Altitude (Operating) | Support operation up to 3050 m with ASHRAE class deratings | |
Humidity (Shipping) | 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) | |
Shock | Operating | Half sine, 2 g, 11 mSec |
Unpackaged | Trapezoidal, 25 g, velocity change is based on packaged weight | |
Packaged | Product Weight: ≥ 40 to < 80 Non-palletized free fall height = 18 inches Palletized (single product) free fall height = NA | |
Vibration | 5 Hz to 500 Hz 2.20 g RMS random | |
Packaged | 5 Hz to 500 Hz 1.09 g RMS random | |
AC-DC | Voltage | 90 Hz to 132 V and 180 V to 264 V |
Frequency | 47 Hz to 63 Hz | |
Source Interrupt | No loss of data for power line drop-out of 12 mSec | |
Surge non-operating and operating | Unidirectional | |