Note
This command is now deprecated and will be removed in a future release.
Description
Sets the system information request frequency.
Whenever the HX appliance sends information to an agent, host endpoint information is also requested. This is called a system information (sysinfo) request. This command sets the maximum time before the appliance requests host information from the agent. When this maximum time is reached, the appliance adds a job request that the agent receives during the next standard poll session.
Syntax
[no] hx server sysinfo-interval <seconds>
Parameters
noUse the no form of this command to reset the system information request interval to the default of 14400 seconds.
sysinfo-interval <seconds>Specify the number of seconds for the system information request interval. Valid values range from 300 to 604800 seconds (7 days). The default is 14400 seconds (4 hours).
Example
The following example sets the system information request interval to one day (86400 seconds):
hostname (config) # hx server sysinfo-interval 86400
User Role
Admin
Command Mode
Configuration
Supported Appliances
This command is supported on the following appliances running the specified releases or later:
Endpoint Security (HX): Release 2.5