Defines the window of time after the timestamp during which information is collected by triage processing.
Syntax
[no] hx server triage window after <seconds>
Parameters
noResets the time window to the default of 86400 seconds (1 day).
after <seconds>Specify the number of seconds after the timestamp during which information is collected by triage processing. Valid values range from 0 through 86400 seconds (1 day). The default is 86400 seconds (1 day).
Example
The following example sets the window after to 86400 seconds:
hostname (config) # hx server triage window after 86400
User role
Admin
Command mode
Config
Supported appliances
This command is supported on the following appliances running the specified releases or later:
Endpoint Security (HX): Release 2.5