Enables an integrated appliance to operate in MVX "sensor" mode, in which the appliance sends all submissions to an MVX cluster for detection and analysis, instead of sending submissions to its on-board MVX analysis engine.
By default, ether1 is the submission interface (used for communication between the appliance and the MVX cluster). Trellix recommends that you configure another management interface (such as ether2) for the submission interface. This prevents the ether1 management interface from becoming too busy, and keeps management and data traffic separate.
If you change from local mode or hybrid mode to sensor mode, must reload the appliance for the change to take effect.
Note
An integrated appliance is a physical appliance with an on-board MVX analysis engine.
Syntax
mvx mode sensor
Parameters
None
Example
The following example enable sensor mode on the nx-2 appliance.
nx-2 (config) # mvx mode sensor MVX sensor mode configuration successful. Please reload the appliance to come up in the configured mode
User role
Admin
Command mode
Config
Supported appliances
This command is supported on the following appliances running the specified releases or later:
Network Security: Release 8.0.0